| Institution | Acquisition device | Global reference | Kinematic | Markers protocol | EMG device | Analog | Analog channels: |
|---|---|---|---|---|---|---|---|
| (Hardware/Software) | system | sampling rate (Hz) | rate (Hz) | Output data | |||
| UNIPD | BTS Smart E |
| 60 | modified version of | BTS Pocket EMG | 1020 | 1-6: FP1; 7-12: FP2; |
| BTS Smart Capture | IORgait [47] | 13-17: EMG | |||||
| UMG | Qualysis |
| 240 | modified version | - | 720 | 1-6: FP1; 8-13: FP2 |
| Qualysis Track Manager (QTM) | of [48] | ||||||
| GU | Vicon |
| 200 | 10 Points Cluster [49] | Aurion Zero Wire | 1000 | 1-6: FP1; 7-12: FP2; |
| Vicon Nexus | 29-44:EMG; | ||||||
| 13-28, 45-52:Biodex | |||||||
| UWA | Vicon |
| 250 | UWA full-body [50] | Noraxon 2400T G2 | 2000 | 1-6: FP1; 7-12: FP2; |
| Vicon Nexus | 13-28: EMG |