Skip to main content

Table 1 Characteristics of the laboratories testing MOtoNMS

From: MOtoNMS: A MATLAB toolbox to process motion data for neuromusculoskeletal modeling and simulation

Institution Acquisition device Global reference Kinematic Markers protocol EMG device Analog Analog channels:
  (Hardware/Software) system sampling rate (Hz)    rate (Hz) Output data
UNIPD BTS Smart E 60 modified version of BTS Pocket EMG 1020 1-6: FP1; 7-12: FP2;
  BTS Smart Capture    IORgait [47]    13-17: EMG
UMG Qualysis 240 modified version - 720 1-6: FP1; 8-13: FP2
  Qualysis Track Manager (QTM)    of [48]    
GU Vicon 200 10 Points Cluster [49] Aurion Zero Wire 1000 1-6: FP1; 7-12: FP2;
  Vicon Nexus       29-44:EMG;
        13-28, 45-52:Biodex
UWA Vicon 250 UWA full-body [50] Noraxon 2400T G2 2000 1-6: FP1; 7-12: FP2;
  Vicon Nexus       13-28: EMG
  1. Four institutions are involved: Department of Information Engineering, University of Padova, Italy (UNIPD), Department of Neurorehabilitation Engineering, Georg August University in Gottingen, Germany (UMG), Centre of Musculoskeletal Research, Griffith University, Gold Coast, Australia (GU), and School of Sport Science, Exercise and Health, University of Western Australia, Perth, Australia (UWA)